Product name | Name | 4 million infrared thermal imaging temperature measurement dual-spectrum tube machine |
Model | STD-8TX843C3-RE01 | |
Thermal imaging parameters | Sensor type | Vanadium oxide uncooled infrared focal plane detector |
Thermal imaging resolution | 256*192 | |
Pixel size | 12μm | |
Band | 8~14 μm | |
Thermal sensitivity | <50mK @25℃,F#1.0,25Hz | |
Focal length | 3.2mm F1.1、FOV 56°* 42° | |
Frame rate | ≤25Hz | |
Temperature measuring parameters | Measuring range | 35℃~45℃ |
Measuring accuracy | ± 0.3℃ (with black body) | |
Measuring distance | 1M~3M | |
Multi-target temperature measurement | Support | |
Visible light parameters | Sensor type | 1/1.8" CMOS low illumination |
Max. resolution | 400W(2560×1440) | |
Video coding standard | H.264B、H.264M、H.264H、H.265、MJPEG、SVC | |
Lens interface | M12 | |
Focal length | 9mm fixed focus lens | |
Professional intelligence | Smart function | Face detection, face tracking, face optimization, face attributes, face recognition, face exposure, face enhancement |
Face capture performance | At the same time, it can detect up to 30 faces; the minimum and maximum pixels of the detection face can be set, and the detection area can be set | |
Face cutout, half body cutout, full body cutout; capture rate not less than 98%, repeat capture rate less than 5% | ||
Face capture mode | Optimal mode, automatic mode, monitoring mode; number of snapshots and time can be set | |
Face attribute analysis | Age, gender, masks, glasses, expressions, etc. | |
Face recognition efficiency | Recognition accuracy rate ≥99.50%, recognition speed ≤0.2S | |
Face database management | Management of up to 3 face libraries, maximum 30,000 face libraries, storage of 100,000 comparison records | |
Face recognition efficiency | Recognition accuracy rate ≥99.50%, recognition speed ≤0.2S | |
Software function | Parameter settings | Video adjustment, alarm sensitivity setting, area of interest, etc. |
Abnormal temperature alarm | High temperature alarm in face area, automatic alarm snapshot | |
Historical data query | Query historical alarm data, process historical alarm data | |
Temperature correction | Supports automatic temperature correction of body surface | |
Hardware interface | Communication Interface | 1 10/100M adaptive Ethernet port |
Other interfaces | Alarm: 1 in 1 out; audio: 1 in 1 out; 1 485 interfaces | |
Local storage | Micro SD/SDHC/SDXC card (maximum 256G), support interrupted network transfer | |
Signal interface | 1 way RS485 interface | |
General specification | Power input | DC12V±20% power supply, power consumption ≤10W |
Environment adaptability | Working temperature: 10~50℃ <90% (non-condensing) | |
Size(mm) | 227(L)*106(W)*100(H) (Not included antenna) | |
Protection level | Indoor use |
Product size (unit mm):